2.2.2 Electrical
Connections
The TC1200-0X00 Scan Engine is equipped with an 8-pin and a 10-pin DF13 connector for
connection to the power supply and input/output signals. The details of the connector pins
are indicated in the following table:
Figure 5 – 10 and 8-pin Connectors
J1
Pin Signal
Description
1
D-
USB Data negative
2
D+
USB Data positive
3
GND
power ground
4
GND
power ground
5 TX
transmit
data
6 RTS
NOT
USED
7 RX
receive
data
8 CTS
NOT
USED
9 VCC
+5Vdc
10 GND
power
ground
J2
Pin Signal
Description
1
GND
power ground
2
NC
3
OUT2+
Output 2 positive
4
OUT1/2-
Output 1/2 negative
5
OUT1+
Output 1 positive
6
NC
7
EXT TRIG-
External Trigger Input positive
8
EXT TRIG+
External Trigger Input negative
Table 3 - TC1200 Scan Engine Pinout