REFERENCES
117
5
ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK character from the host
following label transmission. The selectable timeout range is 200 ms to 15,000 ms (15
seconds) in 200 ms increments. A selection of 0 disables the timeout.
To set this value:
1. Determine the desired setting in milliseconds (x 200 ms). (0-75).
2. Use the Chart
in
Appendix C
to find the hex equivalent for the desired numeric value.
3. Go to
page 40
and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter
Programming Mode.
4. Scan the barcode: SELECT ACK NAK TIMEOUT VALUE.
5. Scan the two hex equivalent characters from the keypad in
Appendix B
that represent the
numeric value determined in step 1 above.
NOTE
If you make a mistake before the last character, scan the CANCEL barcode
to abort and not save the entry string. You can then start again at the
beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure.
ACK NAK Retry Count
This feature specifies the number of times the reader retries a label transmission due to a
retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the
count (no retries), and a selection of 255 specifies unlimited retries.
To set this feature:
1. Determine the desired number of retries. (0-255).
2. Use the Chart
in
Appendix C
to find the hex equivalent for the desired numeric value.
3. Go to
page 40
and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter
Programming Mode.
4.
Scan the barcode: SELECT ACK NAK RETRY COUNT.
5. Scan the two hex equivalent characters from the keypad in
Appendix B
that represent the
numeric value determined in step 1 above.
NOTE
If you make a mistake before the last character, scan the CANCEL barcode
to abort and not save the entry string. You can then start again at the
beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure.
Summary of Contents for TC1200
Page 1: ...TC1200 Reference Manual...
Page 8: ...viii C ASCII HEX DECIMAL CHART 144 D RESERVED CHARACTERS 146...
Page 124: ...Enter Exit Configuration CODE SELECTION PmI 112 STITCHING Disable CMSST00mz Enable CMSST01m...
Page 154: ...TC1200 REFERENCE MANUAL 142 B B KEYPAD 0 0 1 2 1 2 3 4 3 4B 5 6 5D 6F 7 8 7H 8J 9 A 9L A B B...
Page 155: ...KEYPAD 143 B C C D E Db Ed F Ff CANCEL o...
Page 160: ...www automation datalogic com...