![Datalogic TC1200 Reference Manual Download Page 36](http://html1.mh-extra.com/html/datalogic/tc1200/tc1200_reference-manual_4199290036.webp)
TC1200 REFERENCE MANUAL
24
3
CODE SELECTION
Description
Parameter Value
Code 39
Code 39
Disable
C3EN
00
Enable
01
Code 39 Full ASCII
Disable
C3FA
00
Enable
01
Code Length Control
Variable
C3LC
00
Fixed
01
Set Length
Length 1 (or Min Length) from 1 to 50 characters
C3L1
q
Length 2 (or Max Length) 0 or from 1 to 50 characters
C3L2
q
Code 32 (Italian Pharma)
Disable
P3EN
00
Enable
01
Code 32 Check Tx
Disable
P3CT
00
Enable
01
Code 32 Start/Stop Tx
Disable
P3SS
00
Enable
01
Check Options
Check Calculation
Disable
C3CC
00
Enable Standard Check
01
Enable Mod-7 Check
02
Enable Italian Post Check
04
Enable Daimler Chrysler Check
08
Code 39 Check Tx
Disable
C3CT
00
Enable
01
Code 39 Start/Stop Tx
Disable
C3SS
00
Enable
01
Decoding Options
Minimum Reads
One Read
C3MR
01
Two
Reads
02
Three
Reads
03
Four
Reads
04
Decoding Level
Disable
C3DL
00
Level
1
01
Level
2
02
Level
3
03
Level
4
04
Level
5
05
Interdigit Ratio
Any ratio or 1 to 10
C3IR
r
Character Correlation
Disable
C3CO
00
Enable
01
Quiet Zones
Quiet Zone on One Side
C3LO
01
Quiet Zones on Two Sides
02
Auto
03
Virtual Quiet Zones on Two Sides
04
Small Quiet Zones on Two Sides
05
Stitching Disable
C3ST
00
Enable
01
q
= Hex value from
00
to
32
representing the decimal number
r
= Hex value from
00
to
0A
representing the decimal number of the interdigit space/module ratio (00 = any ratio)
Summary of Contents for TC1200
Page 1: ...TC1200 Reference Manual...
Page 8: ...viii C ASCII HEX DECIMAL CHART 144 D RESERVED CHARACTERS 146...
Page 124: ...Enter Exit Configuration CODE SELECTION PmI 112 STITCHING Disable CMSST00mz Enable CMSST01m...
Page 154: ...TC1200 REFERENCE MANUAL 142 B B KEYPAD 0 0 1 2 1 2 3 4 3 4B 5 6 5D 6F 7 8 7H 8J 9 A 9L A B B...
Page 155: ...KEYPAD 143 B C C D E Db Ed F Ff CANCEL o...
Page 160: ...www automation datalogic com...