5
Keyboard Intercode Delay
This parameter specifies the intercode delay between the end of one code and the beginning
of the next. The delay can be set within a range of zero (0) to 99 seconds in 1 second
increments. A setting of zero specifies no delay.
To set the delay:
1. Determine the desired setting in seconds. (0-99).
2. Use the Chart
in
Appendix C
to find the hex equivalent for the desired numeric value.
3. Go to
page 43
and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter
Programming Mode.
4. Scan the barcode: SELECT INTERCODE DELAY.
5. Scan the two hex equivalent characters from the keypad in
Appendix B
that represent the
numeric value determined in step 1 above.
NOTE
If you make a mistake before the last character, scan the CANCEL barcode
to abort and not save the entry string. You can then start again at the
beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit.
This completes the procedure.
5.2 READING PARAMETERS
5.2.1 Illumination
Mode
Illumination Mode
Selects the illumination mode for the reader. The illumination mode can be used to:
to increase the overall diode life
to reduce power consumption;
to turn off the illuminator for safety purposes.
Selections:
Disabled
: the illuminator is always off.
Enabled
: the illuminator is always on.
Triggered
: the illuminator is turned on when the reading phase starts. The illuminator is
turned off as soon as the code(s) are read or when the reading phase ends.
NOTE
The Triggered selection is ignored for Automatic and Test Operating
Modes.
Summary of Contents for TC1200
Page 1: ...TC1200 Reference Manual...
Page 8: ...viii C ASCII HEX DECIMAL CHART 144 D RESERVED CHARACTERS 146...
Page 124: ...Enter Exit Configuration CODE SELECTION PmI 112 STITCHING Disable CMSST00mz Enable CMSST01m...
Page 154: ...TC1200 REFERENCE MANUAL 142 B B KEYPAD 0 0 1 2 1 2 3 4 3 4B 5 6 5D 6F 7 8 7H 8J 9 A 9L A B B...
Page 155: ...KEYPAD 143 B C C D E Db Ed F Ff CANCEL o...
Page 160: ...www automation datalogic com...