6
128
Code 39
Defaults
Scanner
Type
Code
Parameter
Description
I.D.#
Accept.
Input
Mi
n
Max
Factory
Laser
2D Image
r
Enter 1 for On and 0 for Off
Enable
Enables/disables the Code
39 symbology.
0100
On or Off
Off
On
On
√
√
Enable
Aggressive
Decoding
Enables more aggressive
decoding algorithms to be
used in order to scan hard
to read labels.
0101
On or Off
Off
On
Off
√
Enable
Checksum
Requires the use of
checksum characters to
verify a bar code.
0102
On or Off
Off
Off
Off
√
√
Send
Checksum
Instructs the terminal to
include the checksum in the
label transmission.
0103
On or Off
Off
Off
Off
√
√
Full ASCII
Mode
Supports the entire ASCII
character set by replacing
various encoded ASCII
characters with their
corresponding.
0105
On or Off
Off
On
On
√
√
Minimum
Label
Length
Set the minimum label
length to be less than or
equal to maximum label
length.
0120
01 - 50
01
01
01
√
√
Maximum
Label
Length
This feature specifies the
maximum allowable length
of a Code 39 label. The
length includes check and
data characters. Maximum
Label Length should be
greater than or equal to
Minimum Label Length.
0121
01 - 50
01
50
20
√
√
Read
Verification
Sets the number of times a
label must be read before it
is transmitted.
0122
01 - 04
01
02
01
√
√
User ID
Specifies the symbology
identifier (if any) that is sent
when parameter Send Code
ID (Index 0025) is set to 3.
ASCII code zero (null) is
used to indicate that an
identifier is not to be sent for
the symbology.
0123
Any
single
ASCII
character
(00 = Off)
‘C’ ‘C’ ‘C’
√
√