![Datalogic Skorpio X3 User Manual Download Page 143](http://html.mh-extra.com/html/datalogic/skorpio-x3/skorpio-x3_user-manual_512470143.webp)
135
Universal Product Code-A (UPC-A)
Defaults
Scanner
Type
Code
Parameter
Description
I.D.# Accept.
Input
Mi
n
Max
Factory
Laser
2D Image
r
Enter 1 for On and 0 for Off
Enable
Enables/disables the
UPC-A symbology.
0500
On or Off
Off
On
On
√
√
Enable
Aggressive
Decoding
Enables more aggressive
decoding algorithms to be
used in order to scan hard
to read labels.
0501
On or Off
Off
On
Off
√
√
Send
Check Digit
Includes check digit in the
label which is transmitted.
0502
On or Off
Off
On
Off
√
√
Send System
Digit
Includes the system digit
in the label transmission.
For UPC-A, the system
digit is always zero.
0503
On or Off
Off
On
On
√
√
Convert
UPC-A to
EAN-13
Instructs the decoder to
expand UPC-A labels to
their EAN-13 equivalents.
Any EAN-13 parameters
will then apply to the
result.
0504
On or Off
Off
On
Off
√
√
Read
Verification
Sets the number of times
a label must be read
before it is transmitted.
0520
01 - 04
01
02
01
√
User ID
Specifies the symbology
identifier (if any) that is
sent when parameter
Send Code ID (Index
0025) is set to 3. ASCII
code zero (null) is used to
indicate that an identifier is
not to be sent for the
symbology.
0521
Any
single
ASCII
character
(00 = Off)
‘A’ ‘A’ ‘A’
√
√