6
156
Defaults
Scanner
Type
Code
Parameter
Description
I.D.# Accept.
Input
Mi
n
Max
Factory
Laser
2D Image
r
Automatic
Good Read
Enable automatic
Good Read on a
successful read.
0010 On
or
Off
On
On
On
√
√
Enable Green
Spot
Enable Green
Spot with Good
Read.
0011 On
or
Off
On
On
On
√
√
Enable Good
Read LED
Enable LED with
Good Read.
0013 On
or
Off
Off
On
On
√
√
Enable Good
Read Vibrate
Enable
Enable Vibration
with Good Read.
0012 On
or
Off
Off
On
On
√
√
Remove Non-
Printables
Removes all
characters in the
range 0x00 - 0x31
or 0x7F - 0x9F
from the label
data. The
min/max length
checks made for
each symbology
are made before
any characters
are removed.
Characters in the
code ID, prefix,
suffix, or
separator will not
be removed.
0018 On
or
Off
Off
Off
Off
√
√
Group
Separator
Substitution
Each occurrence
of the GS
character (ASCII
code 0x1D) in the
label data will be
substituted for the
character defined
by this
parameter. The
value 0 (NUL) is
considered a valid
replacement
character and
cannot be used to
remove GS
characters.
002C
The maximum number
of data characters is
127. All defined Unicode
characters are valid.
GS GS GS
√
√
Only a single character can be programmed with a programming label; strings can only be programmed in the
Decoding control panel applet.