151
MicroPDF417
Defaults
Scanner
Type
Code
Parameter
Description
I.D.#
Accept.
Input
Mi
n
Max
Factory
2D Image
r
Enter 1 for On and 0 for Off
MicroPDF417
Enable
Enables/disables the
MicroPDF417 symbology.
0A08
On or Off
Off
On
Off
√
MicroPDF417
Minimum
Set the minimum bar code
label length to be less than
or equal to maximum label
length.
0A24 1
-
366 1
1
1
√
MicroPDF417
Maximum
This feature specifies the
maximum allowable length
of a label. The length
includes check and data
characters, if applicable.
Maximum Label Length
should be greater than or
equal to Minimum Label
Length.
0A25 1
-
366 1 366 366
√
MicroPDF417
User
Code ID
Specifies the symbology
identifier (if any) that is
sent when parameter Send
Code ID (Index 0025) is
set to 3. ASCII code zero
(null) is used to indicate
that an identifier is not to
be sent for the symbology.
0A27
Any
single
ASCII
character
(00 = Off)
‘a’ ‘a’ ‘a’
√