![Datalogic Skorpio X3 User Manual Download Page 140](http://html.mh-extra.com/html/datalogic/skorpio-x3/skorpio-x3_user-manual_512470140.webp)
6
132
Code 128
Defaults
Scanner
Type
Code
Parameter
Description
I.D.#
Accept.
Input
Mi
n
Max
Factory
Laser
2D Image
r
Enter 1 for On and 0 for Off
Enable
Enables/disables the Code 128
symbology.
0408
On or Off
Off
On
On
√
√
Enable
Aggressive
Decoding
Enables more aggressive decoding
algorithms to be used in order to
scan hard to read labels.
0409
On or Off
Off
On
Off
√
GS1-128
Enable
Enable GS1-128 variant of Code
128 (independent of Code 128).
040C
On or Off
Off
On
Off
√
√
Code 128
Extended
ASCII Enable
Enable Extended ASCII character
conversion. This enables the ability
of Code 128 labels to use the FNC4
character to encode Extended ASCII
characters, as defined by the latest
Code 128 symbology specification.
040F
On or Off
Off
On
On
√
Minimum
Label
Length
Set the minimum label length to be
less than or equal to maximum label
length.
0424
01 - 80
01
01
02
√
√
Maximum
Label
Length
This feature specifies the maximum
allowable length of a Code 128
label. The length includes check and
data characters. Maximum Label
Length should be greater than or
equal to Minimum Label Length.
0425
01 - 80
01
80
40
√
√
Read
Verification
Sets the number of times a label
must be read before it is transmitted.
0426
01 - 04
01
02
01
√
√
User ID
Specifies the symbology identifier (if
any) that is sent when parameter
Send Code ID (Index 0025) is set to
3. ASCII code zero (null) is used to
indicate that an identifier is not to be
sent for the symbology.
0427
Any
single
ASCII
character
(00 = Off)
‘K’ ‘K’ ‘K’
√
√