Summary of Contents for SC4000

Page 1: ...SC4000 Reference Manual...

Page 2: ...ic Automation S r l Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U ID NET and Genius are trademarks of Datalogic Automa...

Page 3: ...1 1 Power Source Jumper Settings 9 4 1 2 Host 2 Shield Jumper Settings 9 4 1 3 Source Chassis Grounding Jumper Settings 9 4 1 4 ID NET Host 1 Shield Jumper Settings 10 4 2 Network Bus Termination 10...

Page 4: ...Master to Serial Host 36 6 3 SC4000 ID NET Multidata Master to Serial Host and WebSentinel Supervisor 37 6 4 SC4000 ID NET Multidata Master Fieldbus Slave to Host Fieldbus Master 38 6 5 SC4000 ID NET...

Page 5: ...e Manuals provided as supplementary documentation on CD ROM SERVICE AND SUPPORT Datalogic provides several services as well as technical support through its website Log on to www automation datalogic...

Page 6: ...e must accept any interference received including interference which may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital device pursu...

Page 7: ...3 Figure A Indicator LEDs 1 Display 4x20 Characters 2 Compression Connectors 5 5 IP65 protection cover when not using 25 pin Optional Passthrough Device Connector 6 3 Key Keypad 3 Cover Screws 4 Host...

Page 8: ...Selector Power Source Selector 6 Data Source Port Connector Indicator LEDs 7 Auxiliary Port Connector 8 IP65 Host Interface Module Connector 9 Standard Host Interface Module Connector 10 Spring Clamp...

Page 9: ...r to the most common fieldbus systems Ease of Installation Installation is simplified thanks to accessible through holes for mounting screws with closed device Optional adapters are available for fast...

Page 10: ...eed data collection from up to 31 reading stations ID NET interface for data collection network Open architecture allows comfortable connectivity to Ethernet TCP IP Profibus DeviceNet Ethernet IP and...

Page 11: ...ACC1822 BA900 Two Cable Glands Panel 93ACC1847 1 3 SUPPORTED READING DEVICES The following reading devices can be connected as Slave nodes in an ID NET network through a passive CBX100 connection box...

Page 12: ...the SC4000 and all the parts supplied with the equipment are present and intact when opening the packaging the list of parts includes SC4000 ID NET Controller with IP65 25 pin protection cover Quick R...

Page 13: ...INSTALLATION 2 2 2 OVERALL DIMENSIONS The diagram below gives the overall dimensions of the SC4000 and shows the two mounting through holes Mounting Holes mm inch Figure 1 Overall Dimensions 5...

Page 14: ...G THE SC4000 To install the SC4000 or during normal maintenance it is necessary to open it by unscrewing the four cover screws CAUTION The SC4000 must be disconnected from the power supply during this...

Page 15: ...3A polarity insensitive O3B Output 3B polarity insensitive V Power Source Other I O I3A Input 3A polarity insensitive I4A Input 4A polarity insensitive to 25 pin connector only V Power Reference Other...

Page 16: ...additional reading device in Pass Through e g Hand Held Reader The input power signals Vdc GND and Earth as well as the network signals REF ID ID and Shield and RTX RTX and SGND are repeated to facil...

Page 17: ...om device Power from clamps default Figure 3 Power Source Jumper Settings 4 1 2 Host 2 Shield Jumper Settings The Host Interface 2 shield Shield can be connected to Earth Ground Earth either directly...

Page 18: ...e network cable shield Shield is floating Filtered Earth default Earth floating Equivalent Filter Circuit Figure 6 ID NET Host 1 Shield Jumper Settings 4 2 NETWORK BUS TERMINATION 4 2 1 ID NET Termina...

Page 19: ...vices this resistor MUST be OFF disabled This switch must also be OFF disabled when Host Interface Modules are used 4 2 3 Host 2 RS485 HD Termination OFF ON Figure 9 Host 2 RS485 HD Termination Resist...

Page 20: ...en 7 Software Configuration Controlled Host Interface Network 8 ID NET Slave Synchronized 9 ID NET Slave Multidata The Net Type selector switch allows setting the ID NET network ID NET Masters communi...

Page 21: ...address for Ethernet IP and Profinet interfaces These settings correspond to the IP Addressing parameter in Genius 777 Remote Assignment through the IPConfig application available on the reader CD RO...

Page 22: ...audrate is selected through the baudrate switch and must match the Master ID NET baudrate The settings are ID NET Baudrate Switch 0 19200 Baud 5 500 kBaud 1 38400 Baud 6 1 MBaud 2 57600 Baud 7 Reserve...

Page 23: ...es of the system cables by stripping the insulation back approximately 1 cm Using a device such as a screwdriver push down on the lever directly next to the clamp see Figure 13 Insert the wire into th...

Page 24: ...live and are not protected from polarity inversion Disconnect the power supply when working inside the SC4000 OFF ON Figure 14 Power Switch ON OFF Positions V in Earth Ground Power Supply VGND Figure...

Page 25: ...ring clamp terminal blocks The host serial interface types and their line parameters baud rate data bits etc can be defined by the user via Genius software The RS485 half duplex is automatically set w...

Page 26: ...ntrol Signals If the RTS CTS handshaking protocol is enabled the SC4000 activates the RTS output to indicate a message is to be transmitted The receiving unit activates the CTS input to enable the tra...

Page 27: ...SC4000 Figure 19 RS485 Full duplex Connections using Only TX Signals RS485 Half Duplex Interface The RS485 half duplex 3 wires shield interface is used for polled communication protocols It can be us...

Page 28: ...Genius utility or by the Host Programming Mode 5 3 2 Host 2 Interface The Host 2 port can be used for full RS232 RS485 connectivity to an alternative Host computer It is software selectable and optoi...

Page 29: ...smit Data RX RS485 Receive Data SGND Signal Ground SGND RX485 RX485 TX485 TX485 USER INTERFACE SGND TX TX RX RX SC4000 Figure 22 RS485 Full duplex Connections NOTE For applications that do not use RX4...

Page 30: ...e Transmit Data SGND Signal Ground SGND RTX485 RTX485 USER INTERFACE SGND RTX RTX SC4000 Figure 24 RS485 Half duplex Connections 5 4 ID NET INTERFACE SC4000 features an optoisolated ID NETTM high spee...

Page 31: ...below For Common Power Connections use only 2 wires ID and ID DC Voltage Power cable Vdc GND should be handled as a signal cable i e do not put it together with AC cable Wire dimensioning must be che...

Page 32: ...T Response Time 240 220 200 180 160 140 120 100 80 60 40 20 0 Response Time ms Number of Nodes 500 kbps 250 kbps 125 kbps 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Figure 25 ID NET Response Time CONDIT...

Page 33: ...ELECTRICAL CONNECTIONS 5 Figure 26 ID NET Network Connections with isolated power blocks 25...

Page 34: ...SC4000 REFERENCE MANUAL 5 Figure 27 ID NET Network Connections with Common Power Branch Network 26...

Page 35: ...ELECTRICAL CONNECTIONS 5 Figure 28 ID NET Network Connections with Common Power Star Network 27...

Page 36: ...ons can be made to a PC or Laptop using a straight through cable or a USB RS232 converter 5 1 6 9 Figure 29 9 pin D Sub Female Connector With reference to the 9 pin connector of Figure 29 the followin...

Page 37: ...me Function 2 TX Data Source Aux Interface Receive Data 3 RX Data Source Aux Interface Transmit Data 5 SGND Signal Ground 1 4 6 7 8 9 N C RX TX Reference USER INTERFACE Figure 32 Data Source Auxiliary...

Page 38: ...G READING DEVICE POWER CAUTION Power is available directly to the Input Device independently from the Power Supply Switch inside the SC4000 brown black blue PH 1 Photocell PNP Figure 33 PH 1 External...

Page 39: ...nsitive I2B Input 2 B polarity insensitive V Power Reference Inputs INPUT 2 CONNECTIONS USING READING DEVICE POWER CAUTION Power is available directly to the Input Device independently from the Power...

Page 40: ...Power 5 8 OUTPUTS Two optocoupled general purpose outputs are available The meaning of the two outputs Output 1 and Output 2 can be defined by the user These outputs are typically used when SC4000 is...

Page 41: ...Figure 39 Open Emitter Output Using SC4000 Power Power to Output device Output device Reference Output Device Output Signal Figure 40 Open Collector Output Using SC4000 Power OUTPUT CONNECTIONS USING...

Page 42: ...olarity insensitive input Input 4 only available to device connected to the 25 pin connector one optocoupled polarity insensitive output Output 3 T O3A Output 3A polarity insensitive O3B Output 3B pol...

Page 43: ...2 can be connected to a secondary serial interface Host monitor etc The dotted lines in the figure refer to optional hardware configurations A portable PC can be quickly connected to the SC4000 Auxili...

Page 44: ...ommunication Settings Host 1 Serial Port Line Parameters Communication Protocol Standard Communication Settings Host 1 Serial Port Line Parameters Electrical Interface Baud Rate Parity Data Bits Stop...

Page 45: ...ters ID NET Multidata Master to Serial Host and WebSentinel Supervisor Note Net Type Rotary Switch 7 Address rotary switches are ignored Topology Role Master MULTIDATA System Layout Host 1 Serial Port...

Page 46: ...5 I O PS Host Fieldbus Master 6 Reader ID NET Interface SC4000 ID NET Interface SC4000 Host 1 BMxxx Fieldbus Module Aux Interface for SC4000 Configuration and Genius compatible Slave Reader Configurat...

Page 47: ...ugh checked Data Source device to the Auxiliary port Communication Settings Auxiliary Serial Port Data Pass Through Options Data Destination Gateway checked Data Source device to the Auxiliary port Co...

Page 48: ...a Size Master Output Area Size Data Flow Control Data Consistency According to the Fieldbus application Communication Settings Host 2 Serial Port Line Parameters Communication Protocol Standard Data S...

Page 49: ...d if power polarity is incorrect In this case any optional reading device connected to the 25 pin connector as well as the Backup Module are protected CAUTION If external I O devices are powered throu...

Page 50: ...elease Up or Down arrow keys Select Item press and release Enter key Exit without selecting any item select menu Exit item during or after the execution of a function In this case the following option...

Page 51: ...ius NET Autoset Start searching new nodes Stop searching new nodes Found new node assigned address Replacing device Genius Restore Default Parameters Keep pressed to set default Setting default Defaul...

Page 52: ...ID NET Master saves the configuration of all the reading devices in the network Master and all individual Slaves The Slaves must be configured with the same network baudrate as the Master before perf...

Page 53: ...o r Network State 1 N e t w o r k 1 5 1 6 N e t w o r k 3 1 Where Device OK Device not detected at startup Device detected at startup but not responding to polling Device with diagnostic error Diagno...

Page 54: ...rection U Unknown direction Reading Mask Master Synchronized only P a r t i a l R e a d G 0 9 9 N 0 0 0 M 0 0 0 P 0 0 1 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Four percentage co...

Page 55: ...n Driver DAD Driver USER INTERFACE LED Indicators Power On Polarity Error blue red Trigger yellow IN2 green OUT1 yellow OUT2 green Ready green Host 1 yellow Host 2 green ID NET yellow OUT3 green Displ...

Page 56: ...o 55 Hz EN 60068 2 6 2 g 70 to 200 Hz 2 hours on each axis Bump Resistance 30 g 6 ms EN 60068 2 29 5000 shocks on each axis Protection Class EN 60529 IP65 when compression connectors and reading devic...

Page 57: ...put 1 30 Input 2 31 Inputs 29 J Jumper Settings 9 K Keypad 42 L LEDs 41 M Mechanical Installation 6 N Network Bus Termination 10 Network Parameter Selectors 12 O Other I O 34 Outputs 32 Overall Dimens...

Page 58: ...laws of Member States relating to electromagnetic compatibility and product safety Bas e sur la l gislation des Etats membres relative la compatibilit lectromagn tique et la s curit des produits ber...

Page 59: ...www automation datalogic com...