SE4-PLUS Series
Instruction Manual
37
1 2 3 4
1 2 3 4
ON
ON
The function controls the N.C. contact switching according to the
changes of the OSSD status.
T
c
350 msec time after the OSSD OFF-ON passage when
EDM is carried-out
T
0
100 msec time after the OSSD ON-OFF passage when
EDM is carried-out
The use of non-conform devices may cause
failures.
The periodical testing of the function is
recommended.
The correct dip-switch positioning (dip 3
OFF) for the function activation is shown here aside.
6.6. Blanking function
(only in some models, see section 10 “List of available models”)
The Blanking function deactivates a specific zone of the detection
field in order to guarantee that the presence of an object in this
area does not interrupt the functioning of the controlled machine.
Two Blanking modes can be configured: Floating Blanking and
Fixed Blanking.
These modes can be activated singularly or contemporarily.