6.6.1. Floating Blanking
Allows the Blanking of 1, 2 or 3 beams positioned in any zone of
the detection area. Dip-switches 1 and 2 configure the number of
beams to deactivate.
Floating blanking OFF
ON
ON
Floating Blanking deactivated
Note: Floating Blanking can not be applied on the first top beam
as it carries-out the synchronism functions. If an object
interrupts the first beam during functioning, even if
Floating Blanking is activated, the OSSD outputs open
and the light curtain enters into the BREAK status.
Break
Safety distance change
The activation of the Floating Blanking function provokes a
reduction of the device resolution. Consequently, the safety
distance has to be recalculated according to the real device
resolution (
see table in section 2.2.1
).
ON
1 2 3 4