44
The acquisition of the necessary information is carried-out
interrupting the beams on which the Blanking function has to be
applied. Only one single Blanking area can be memorised and
thus, during TEACH-IN, all the interrupted beams must be
contiguous. If a beam is not deactivated inside the area to
memorise, situation similar to the effort to memorise two
different areas, the system enters in “ Blanking functioning
failure” status (
see table
).
The TEACH-IN is confirmed releasing the push-button. The
OSSD outputs return active at the push-button releasing.
Note: TEACH-IN can not be applied on the first top beam as it
carries-out the synchronism functions. If at the push-
button release, the first beam is deactivated, the system
enters into “Blanking functioning failure” status
(see table
on next page).
OK
NO