TOP PANEL INTERFACE

 

Opening the dust cover provides access to the top panel interface. The top panel interface consists of the RUN/PRG/ADJ 
mode switch, LO/DO switch, +/SET/- Navigation key, dual red/green digital displays, and output LED. 

 

RUN/PRG/ADJ Mode Switch

 

 

The RUN/PRG/ADJ mode switch puts the sensor in RUN, PRG (Program), or ADJ (Adjust) mode. 
RUN mode allows the sensor to operate normally and prevents unintentional programming changes via 
the +/SET/- button. PRG mode allows the sensor to be programmed through the display driven 
programming menu (see 

Program Mode 

below). 

ADJ mode allows the user to perform Expert TEACH/SET methods and Manual Adjust (see 

Adjust 

Mode 

below). 

 

LO/DO Switch

 

 

The LO/DO switch is used to select Light Operate or Dark Operate mode. In Light Operate mode, the 
output is ON when the sensing condition is above the threshold (for Window SET, the output is ON 
when the sensing condition is inside the window). In Dark Operate mode, the output is ON when the 
sensing condition is below the threshold (for Window SET, the output is ON when the sensing condition 
is outside the window). 

 

+/SET/- Navigation key

 

 

The +/SET/- Navigation key is a 3-way button. The +/- positions are engaged by rocking the button left/ 
right. 
The SET position is engaged by clicking down the button while the rocker is in the middle position. All 
three button positions are used during PRG mode to navigate the display driven programming menu. 
During ADJ mode, SET is used to perform TEACH/SET methods and +/- are used to manually adjust 
the threshold(s). The Navigation key is disabled during RUN mode, except when using Window SET, 
see 

Window SET

.

 

 

Red/Green Digital Displays

 

 

During RUN and ADJ mode, the Red display shows the signal level and the Green display shows the 
threshold. 
During PRG mode, both displays are used to navigate the display driven programming menu. 

 

       

Output LED

 

The output LED provides a visible indication when the output is activated. 

 
 
 
 

Remote Input / IO-Link

 

For more information about how to perform TEACH/SET methods, to program the sensor remotely, 
or to interface with the sensor via IO-Link, see the www.datalogic.com. 

 

 

 
 

 

Run Mode

 

Run mode allows the sensor to operate normally and prevents unintentional programming changes. 
The +/SET/- Navigation key is disabled during RUN mode, except when using Window SET, see 

Window SET

 

Summary of Contents for S70

Page 1: ...or malfunction can cause either an energized or de energized sensor output condition Outputs Connector1 S70 2 E1 N Single NPN 2 m cable 4 wire S70 2 E1 P Single PNP S70 5 E1 N Single NPN Integral M8 Pico QD connector 4 pin S70 5 E1 P Single PNP S70 5 E1 PZ Dual outputs 1 push pull IO Link and 1 PNP complementary outputs S70 5 E2 N Single NPN Integral M8 Pico QD connector 4 pin S70 5 E2 P Single PN...

Page 2: ... Move the fiber clamp backward to lock the fiber s 5 Close the dust cover Fiber Adapters NOTE If a thin fiber with less than 2 2 mm outer diameter is used install the fiber adapter provided with the fiber assembly to ensure a reliable fit in the fiber holder Datalogic includes the adapters with all fiber assemblies Fiber Outer Diameter mm Adapter Color Ø 1 0 Black Ø 1 3 Red Ø 2 2 No adapter needed...

Page 3: ...the sensing condition is outside the window SET Navigation key The SET Navigation key is a 3 way button The positions are engaged by rocking the button left right The SET position is engaged by clicking down the button while the rocker is in the middle position All three button positions are used during PRG mode to navigate the display driven programming menu During ADJ mode SET is used to perform...

Page 4: ...e value see Technical Data pag 17 Auto thr Click SET to enter choice list DISPLAY LOOP oFF On OFF dLY Click SET to enter choice 0 ms or to set value 9999 ms OFF 1Sho Click SET to enter choice list 0 ms or to set value 9999 ms SET Navigation key To scroll through menu lists Press or To enter a choice list or to select and save Click SET To exit a choice list without saving Press and hold SET for 2 ...

Page 5: ...al Position adjusted by Manual Adjust Most Light saturated signal Figure 2 Two Point TEACH Light Operate shown The Output ON and OFF conditions can be reversed by using the LO DO Light Operate Dark Operate switch see LO DO Switch in Top Panel Interface Two Point TEACH and Manual Adjust Moves switching threshold value up or down to make adjustments Slide Mode switch to ADJ to enter Adjust mode Pres...

Page 6: ...ngle pulse the remote input 4 Return to Run mode Method Action Result SET Button Move the Mode switch to RUN Display Red Signal Level Green Threshold Remote Input No action is required sensor returns to RUN mode automatically Dynamic TEACH Teaches on the fly Establishes a single switching threshold Threshold can be adjusted using and Navigation key Manual Adjust Dynamic TEACH is best used when a m...

Page 7: ... 1 Enter Adjust Mode Method Action Result SET Button 5 Set Mode switch to ADJ Display Red Signal Level Green Threshold Remote Input 6 No action required sensor is ready for Dynamic TEACH method 2 Enter Dynamic TEACH Method Action Result SET Button Click the SET Navigation key Display Flashes dYn tch then holds on 1234 dYn Remote Input T Single pulse remote input 3 Present ON and OFF Conditions Met...

Page 8: ...ange state Sensing window center can be adjusted using and Navigation key Manual Adjust Recommended for applications where a product may not always appear in the same place or when other signals may appear See Program Mode in the user s manual for programming the Offset Percent setting to increase decrease the window size A single sensing condition is presented and the sensor positions window thre...

Page 9: ... Action Result SET Button Present sensing condition Click the SET Navigation key Threshold Condition Accepted Displays read wInd SEt then alternate PASS with Offset10 Sensor returns to Adjust mode Threshold Condition Not Accepted Displays read wInd SEt then alternate FAIL with minimum Offset10 for sensing condition Sensor returns to Adjust mode Remote Input Present sensing condition T Single pulse...

Page 10: ...nel Interface Threshold position adjusted by Manual Adjust Sensor positions threshold a programmable offset below the presentedcondition Output OFF Output ON Darkest no signal Condition Presented Most Light saturated signal Figure 6 Light SET Light Operate shown Light SET and Manual Adjust Moves switching threshold value up or down to make adjustments Slide Mode switch to ADJ to enter Adjust mode ...

Page 11: ...ented condition Any condition lighter than the threshold condition causes the output to change state Threshold can be adjusted using and Navigation key Manual Adjust Recommended for applications where only one condition is known for example a stable dark background with varying lighter targets See Program Mode for programming the Offset Percent setting A single sensing condition is presented and t...

Page 12: ... Signal Level Green Threshold Remote Input 15 No action required sensor is ready for Dark SET method 2 SET Sensing Condition Method Action Result SET Button Present sensing condition Click the SET Navigation key Threshold Condition Accepted Displays read dr SEt then alternate PASS with Offset16 Sensor returns to Adjust mode Threshold Condition Not Accepted Displays read dr SEt then alternate FAIL ...

Page 13: ... no signal Condition Presented Most Light saturated signal Figure 8 Calibration SET Light Operate shown Calibration SET and Manual Adjust Moves switching threshold value up or down to make adjustments Slide Mode switch to ADJ to enter Adjust mode Press to increase press to decrease GREEN display shows the switching threshold value 2 seconds after adjustment the GREEN display will flash 3 times to ...

Page 14: ...r returns to Adjust mode Threshold Condition Unacceptable Displays read cAL SEt then flashes FAIL Sensor returns to Adjust mode Remote Input Present sensing condition T Single pulse the remote input 1 Return to RUN Mode Method Action Result SET Button Move Mode switch to RUN Display Red Signal Level Green Threshold Remote Input No action required sensor returns to RUN mode automatically ...

Page 15: ...he taught conditions sufficiently exceeds the required minimum minor sensing variables will not affect sensing reliability 600 PASS The difference of the taught conditions greatly exceeds the required minimum very stable operation Percent Offset after SET The Window Dark and Light SET methods will flash a offset on the displays after a PASS or FAIL SET Result Offset Meaning PASS with Offset Displa...

Page 16: ... voltage NPN 1 5 V PNP IO Link 2 V IO Link 50 A at 30 VDC OutputProtection Protected against output short circuit continuous overload transient over voltages and false pulse on power up Output Response Time High Speed 200 μs Standard 500 μs Long Range 2 ms Extra Long Range 5 ms Super High Speed 10 μs High Speed 15 μs Fast 50 μs Standard 250 μs Medium Range 500 μs Long Range 1000 μs Repeatability H...

Page 17: ...imensions in mm Datalogic S r l Via S Vitalino 13 40012 Calderara di Reno Italy Tel 39 051 3147011 Fax 39 051 3147205 www datalogic com Datalogic reserves the right to make modifications and improvements without prior notification 821002592 Rev C 182859C ...

Reviews: