12
SET Button: 0.04 seconds "Click" 0.8 seconds
Remote Input: 0.04 seconds T 0.8 seconds
See
Troubleshooting
on page 16 for more explanation of the % Offset displayed after the Dark SET method.
14
15
16
Dark SET and Manual Adjust
Moves switching threshold value up or down to make adjustments
•
Slide Mode switch to ADJ to enter Adjust mode
•
Press "+" to increase; press "-" to decrease
GREEN display shows the switching threshold value
2 seconds after adjustment, the GREEN display will flash 3 times to confirm
•
Slide Mode switch to RUN to complete operation
Follow these steps to perform a Dark SET:
1.
Enter
Adjust
Mode.
Method
Action
Result
SET Button
14
Set Mode switch to ADJ
Display: Red - Signal Level; Green -
Threshold
Remote Input
15
No action required; sensor is ready for Dark
SET method
2.
SET
Sensing
Condition.
Method
Action
Result
SET Button
•
Present sensing condition
•
Click the SET Navigation key
Threshold Condition Accepted
Displays read "
dr SEt
" then alternate
"
PASS
" with % Offset
16
; Sensor
returns to Adjust mode
Threshold Condition Not Accepted
Displays read "
dr SEt
" then alternate
"
FAIL
" with minimum % Offset
16
for
sensing condition; Sensor returns to
Adjust mode
Remote Input
•
Present sensing condition
T
•
Single-pulse the remote input
3.
Return to RUN Mode.
Method
Action
Result
SET Button
Move Mode switch to RUN
Display: Red - Signal Level;
Green - Threshold
Remote Input
No action required; sensor returns to RUN
mode automatically
Remember
: Manual adjustments are disabled when Auto Thresholds are ON
Note:
TEACH Selection must be programmed to
dr SEt
(see
Program Mode
)