Enter/Exit Programming Mode
Product Reference Guide
51
Global AIM ID
This feature enables/disables addition of AIM IDs for all sym-
bology types.
AIM label identifiers (as opposed to custom characters you select yourself as
with label identifiers) can be included with scanned bar code data. See
AIM label identifiers consist of three characters as follows:
• A close brace character (ASCII ‘]’), followed by...
• A code character (see some samples in the table below), followed by...
• A modifier character (the modifier character is symbol dependent).
DEFAULT
$CAIEN00(CR)
Global AIM ID = Disable
$CAIEN01(CR)
Global AIM ID = Enable
Table 3
. AIM IDs
Tag Name
AIM ID code
character
AIM ID code
ASCII value
ABC CODABAR
X
58
ANKER PLESSEY
N
4E
AZTEC
z
7A
CHINA SENSIBLE CODE
X
58
CODABAR
F
46
CODE11
H
48
CODE128
C
43
CODE32
A
41
CODE39
A
41
CODE39 CIP
X
58
CODE39 DANISH PPT
X
58