Scanning Features
Product Reference Guide
299
Flash On Time
This feature specifies the ON time for the indicator LED while in Flash Mode.
The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in
100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad
the result with leading zeroes to yield two digits. For example: 0 = 00,
5 = 05, 20 = 20, etc.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT FLASH ON TIME SETTING.
5. Scan the appropriate two digits from the keypad in
representing the duration which was determined in the steps above.
You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See
for examples of how to set this
feature.
Table 44. Flash On Time Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
500ms
1,000ms (1 sec.)
5200ms (5.2
sec.)
9,900ms (9.9 sec.)
2
Divide by 100 (and pad
with leading zeroes to yield
two digits)
05
10
52
99
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT FLASH ON TIME SETTING
5
Scan Two Characters From
‘0’ and ‘5’
‘1’ and ‘0’
‘5’ and ‘2’
‘9’ and ‘9’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for PowerScan PD9530
Page 34: ...Enter Exit Programming Mode 24 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 56: ...Enter Exit Programming Mode 46 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 72: ...62 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 182: ...172 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 214: ...204 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 318: ...References 308 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 322: ...Message Formatting 312 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 360: ...Scancode Tables 350 PowerScan PD9530 PBT9500 PM9500 NOTES...