Product Reference Guide
309
Chapter 5
Message Formatting
Message Formatting is available for PM9500 models only.
For this feature to be operational, the scanner must be set to
Ignore Host Commands (see
A message from the Host to the base must follow these rules:
• If Address stamping options or address delimiter are enabled on the
base, the Host replay must have address field and delimiter too. Other-
wise the message will be ignored. Address delimiter is present only
when address stamping is enabled.
• Address stamping is necessary to correctly route the message to the
PM9500, especially when more than one handheld is linked to the same
base. Address stamping could be disabled if the system is in point to
point configuration. If address stamping is not enabled, the messages
are addressed to the first handheld linked to the base.
• The maximum character length for messages is 48.
• Messages end with “CR” 0x0D ASCII character. The CR character cannot
be contained in the middle.
• Messages cannot start with '$' or # because these are reserved for Ser-
vice mode command
• Base station can receive host message only if Host Commands Obey/
Ignore is set to Ignore.
• Message could be sent to the handheld in response to a Label when
“Transmit mode” require Ack from Host (see transmit mode parameter)
or at any time. When messages are sent not in response to a label must
start with DC2 0x12 ASCII character and could be sent in any transmit
mode setting.
• Message could be sent to all handhelds linked to the base by using a
Multicast message:
“00 00 00 00 2A AA”
• In order to receive a message, handhelds must not be in sleep state.
The format of the ACK from Host message (used for transmission mode 02)
is:
[Scanner_Addr] [Scanner_Addr_delimiter] MESSAGE <CR>
The format of a generic message From Host to HH is:
[Scanner_Addr] [Scanner_Addr_delimiter] DC2 MESSAGE <CR>
where DC2 is ASCII 0x12 (^R) character.
[Items in square brackets are optional.]
• If you want to control the Scanner's beeper from the host, you will also
probably want to disable the good transmission beep that is emitted
when the code is received from the cradle. (See "
The message field can store plain text and escape sequences.
• Escape sequences are interpreted as commands.
Summary of Contents for PowerScan PD9530
Page 34: ...Enter Exit Programming Mode 24 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 56: ...Enter Exit Programming Mode 46 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 72: ...62 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 182: ...172 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 214: ...204 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 318: ...References 308 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 322: ...Message Formatting 312 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 360: ...Scancode Tables 350 PowerScan PD9530 PBT9500 PM9500 NOTES...