Enter/Exit Programming Mode
2D Global Features
190
PowerScan™ PD9530/PBT9500/PM9500
PDF417 Set Length 1
Specifies one of the bar code lengths for
. Length 1 is
the minimum label length if in
Variable Length
Mode, or the first fixed
length if in Fixed Length Mode. Length includes the bar code’s data charac-
ters only. Characters can be set from 0001 to 2,710 characters (pad with
zeroes) in increments of 01. Any value greater than 2,710 will be considered
to be 2,710.
See
for detailed instructions on setting this feature.
$CP4L1
Select PDF417 Length 1 Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in
repre-
senting your desired character(s). End by scanning
the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
0001 = Length 1 is 1 Character
Summary of Contents for PowerScan PD9530