Enter/Exit Programming Mode
206
PowerScan™ PD9530/PBT9500/PM9500
Motion Sensitivity
Defines discrete set of levels for scanner motion sensitivity when in hand-
held use.
$CMOSY00(CR)
Motion Sensitivity = Low
$CMOSY01(CR)
Motion Sensitivity = Medium
DEFAULT
$CMOSY02(CR)
Motion Sensitivity = High
Motionless Timeout
Specifies the waiting time in 100 millisecond ticks to assume that the reader
is in a motionless condition. The selectable range is 500 msec to 25.5 Sec-
onds. When no motion event is detected for a period of time longer than this
timeout, the software assumes the reader is in a motionless condition. This
option relates to such features as Aimer On and Stand Mode Object Sense
scanning with respect to motion. See "
Motionless Timeout" on page 303
References.
$CMOTO
Select Motionless Timeout Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar
code at left followed by three digits from the Alpha-
numeric characters in
rep-
resenting your desired character(s). End by scanning
the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
020 = Motionless Timeout = 2 seconds
Summary of Contents for PowerScan PD9530
Page 34: ...Enter Exit Programming Mode 24 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 56: ...Enter Exit Programming Mode 46 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 72: ...62 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 182: ...172 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 214: ...204 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 318: ...References 308 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 322: ...Message Formatting 312 PowerScan PD9530 PBT9500 PM9500 NOTES...
Page 360: ...Scancode Tables 350 PowerScan PD9530 PBT9500 PM9500 NOTES...