Appendix E — Troubleshooting
Problem: No Data Output.
When the trigger is pulled, the unit beeps and then triple-beeps, but does not output data.
Error Messages (String Output):
None.
Possible Cause:
POWERSCAN D8590 is not connected (USB or Serial) to the PC.
Solution:
1. Check to make sure the PC supports “High Power Devices” (self-powered hubs, some
laptops, etc.). Right-click on
My Computer
in the Windows
Start
menu, select
Properties
,
click the
Device Manager
button on the
Hardware
tab, expand the
Universal Serial
Bus controllers
menu item, right-click on
USB Root Hub
, select
Properties
, and
then select the
Power
tab.
2. Make sure the PC is not allowed to power down the device. Follow the same path
described above, but select the
Power Management
tab instead of the
Power
tab.
Uncheck the
Allow the
computer to turn off this
device to save power
box if it is checked.
Summary of Contents for PowerScan PD8590-DPM
Page 1: ...PowerScan PD8590 DPM Imager Industrial Corded Handheld Bar Code Reader User s Manual...
Page 32: ...2 18 POWERSCAN D8590 User s Manual Send Receive NOTES...
Page 42: ...3 10 POWERSCAN D8590 User s Manual Illumination Sequence NOTES...
Page 58: ...4 16 POWERSCAN D8590 User s Manual Other Communications Settings in ESP NOTES...
Page 64: ...5 6 POWERSCAN D8590 User s Manual Region of Interest NOTES...
Page 84: ...6 20 POWERSCAN D8590 User s Manual Symbology Identifier NOTES...
Page 110: ...9 8 POWERSCAN D8590 User s Manual Terminal Dropdown Menu NOTES...
Page 121: ...POWERSCAN D8590 User s Manual A 5 Appendices USB Cable Pinouts 1 828 80 mm...
Page 127: ......