PRODUCT REFERENCE GUIDE 55
The table below gives the pinout of the CBX100/500 terminal block connectors. Use this
pinout when the Matrix 120™ reader is connected by means of the CBX100/500:
Group
Label
Description
Input Power
Vdc
Power Supply Input V
GND
Power Supply Input Voltage -
Earth
Protection Earth Ground
Inputs
+V
Power Source - External Trigger
I1A
External Trigger A (polarity insensitive)
I1B
External Trigger B (polarity insensitive)
-V
Power Reference - External Trigger
+V
Power Source - Inputs
I2A
Input 2 A (polarity insensitive)
I2B
Input 2 B (polarity insensitive)
-V
Power Reference - Inputs
Outputs
+V
Power Source - Outputs
-V
Power Reference - Outputs
O1+
Output 1 + opto-isolated and polarity sensitive
O1-
Output 1 - opto-isolated and polarity sensitive
O2+
Output 2 + opto-isolated and polarity sensitive
O2-
Output 2 - opto-isolated and polarity sensitive
Auxiliary Interface
Matrix 120™ has not Auxiliary Interface
ID-NET
Matrix 120™ has no ID-NET Interface
Main Interface
RS232
TX
RX
-
-
SGND
RS422 Full Duplex
TX+
*RX+
TX-
*RX-
SGND
* Do not leave floating, see "
RS422 Full Duplex Interface" on page 57
NOTE
To avoid electromagnetic interference when the reader is connected to a
CBX connection box, verify the jumper positions in the CBX as indicated
in its Installation Manual.
Summary of Contents for Matrix 120
Page 1: ...Matrix 120 PRODUCT REFERENCE GUIDE Image Based Reader...
Page 14: ...GENERAL VIEW XIV MATRIX 120...
Page 75: ...INPUTS PRODUCT REFERENCE GUIDE 61 Figure 41 NPN External Trigger Using Matrix 120 Power...
Page 97: ...GLOBAL FOV DIAGRAMS PRODUCT REFERENCE GUIDE 83 Matrix 120 310 xxA Models Digimarc Barcode...
Page 153: ...Reader 2 Reader 3 PASS THROUGH CONFIGURATIONS PRODUCT REFERENCE GUIDE 139...
Page 185: ......
Page 186: ......
Page 187: ......