RAPID CONFIGURATION
18 MATRIX 120™
Automatic Setup
To begin configuration, the reader must be correctly mounted so that its Field of View
covers the application reading area.
1. From the Task Area select Open Device Configuration.
2. The Open Device Configuration window opens showing the list of currently saved
configurations (jobs) saved on the device. For new devices, the only saved job is
the Default configuration. Click OK. The device enters run mode and begins acquir-
ing images.
3. Place an
application specific code
in front of the reader at the correct application
reading distance.
The Matrix 120™ models are factory calibrated at three focus positions (
45, 70 and
125 mm for WVGA models; 45, 80 and 125 mm for MP models
). Using a 2.5 mm
Hex key (Allen wrench), rotate the Focus Adjustment Screw at the back of the
reader to one of these three positions for your application.
Refer to the Reading Diagrams in
Reading Features, starting on page 77
which show
the reading ranges at the different focus positions for Code 128 (1D) and Data
Matrix (2D) codes.
4. Once positioned, stop image acquisition by clicking on the Pause button.
CAUTION
Do not rotate the Focus Adjustment Screw beyond the focus scale limits,
otherwise damage can occur to the focus mechanism.
Summary of Contents for Matrix 120
Page 1: ...Matrix 120 PRODUCT REFERENCE GUIDE Image Based Reader...
Page 14: ...GENERAL VIEW XIV MATRIX 120...
Page 75: ...INPUTS PRODUCT REFERENCE GUIDE 61 Figure 41 NPN External Trigger Using Matrix 120 Power...
Page 97: ...GLOBAL FOV DIAGRAMS PRODUCT REFERENCE GUIDE 83 Matrix 120 310 xxA Models Digimarc Barcode...
Page 153: ...Reader 2 Reader 3 PASS THROUGH CONFIGURATIONS PRODUCT REFERENCE GUIDE 139...
Page 185: ......
Page 186: ......
Page 187: ......