Technical Specifications
310
Gryphon™ I GD44XX/GBT4400/GM440X
Base Station Indications (Cordless Models ONLY)
INDICATION
LEDS
Power-up Complete
Yellow LED on
Reader Disabled by the HOST or the communication
with HOST is not established
Yellow LED blinking ~1Hz
Data/labels are transmitted to the HOST
Yellow LEDs turned off for 100mSec
Programming Mode
Yellow LED blinks quickly
Configuration alignment with the handheld is in
progress
Red LED blinks quickly
Battery charging in progress
Red LED on
Battery charging complete
Green LED on
Battery charger error
Red and Green LEDs off
No handheld is placed on the cradle
Red and Green LEDs off
Base Station Button Indicators
BUTTON PUSH
EVENT
CORDLESS
RED INDICATOR
GREEN
INDICATOR
Push at power-up
force device connection
(Aladdin)
Off
Slow blink
Fast blink
< 1 sec (*)
UV LED On/Off
Off
Off
1 to 5 sec
Paging
Off
Fast blink
5 to 10 sec
Unlink (Only BT)
Off
Slow blink
10 to 15 sec
Reset
Fast blink
Off
15 to 20 sec
Restore custom
defaults
Slow blink
Off
> 20 sec
No action
Off
Off
*Only for models with UV Counterfeit Money Detector, see page 5 for more
details.
Summary of Contents for Gryphon I GM440 Series
Page 42: ...Setup 32 Gryphon I GD44XX GBT4400 GM440X...
Page 46: ...Enter Exit Programming Mode 36 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 60: ...Enter Exit Programming Mode 50 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 102: ...Enter Exit Programming Mode 92 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 248: ...238 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 308: ...References 298 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 338: ...Keypad 328 Gryphon I GD44XX GBT4400 GM440X A B C D E F...
Page 348: ...Scancode Tables 338 Gryphon I GD44XX GBT4400 GM440X NOTES...