Enter/Exit Programming Mode
China Sensible Code
214
Gryphon™ I GD44XX/GBT4400/GM440X
China Sensible Code
Set Length 1
Specifies one of the bar code lengths for
China Sensible Code Length Con-
. Length 1 is the minimum label length if in
Variable Length
Mode, or the
first fixed length if in Fixed Length Mode. Characters can be set from 0001
to 7,827 characters in increments of 0001 (pad with zeroes).
See
for detailed instructions on setting this feature.
$CCSL1
Select China Sensible Code Length 1 Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at left followed by the digits from the Alphanumeric
characters in
r
epresenting
your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start again
at the beginning.
CANCEL
~
DEFAULT
0001 = Length 1 is 1 Character