Message Formatting
300
Gryphon™ I GD44XX/GBT4400/GM440X
when the code is received from the cradle. (See "
).
The message field can store plain text and escape sequences.
• Escape sequences are interpreted as commands.
LED and Beeper Control
The LED control escape sequences are intended to activate the LEDs for
short periods of time and can be used in combination with the Beeper. The
LED and Beeper will be controlled by the system after the entire command
sequence is interpreted.
Example:
ESC [ 6 q ESC [ 3 q ESC [ 7 q
Turns on the green LED, emits a good read tone, and turns off the green
LED.
ESC [ 6 q ESC [ 5 q ESC [ 7 q
Turns on the green LED for 100 ms and then turns off the green LED.
Escape sequences different from those listed will be ignored.
ESC [ 0 q
Emit short High tone + short delay
ESC [ 1 q
Emit short Low tone + short delay
ESC [ 2 q
Emit long Low tone + short delay
ESC [ 3 q
Emit good read tone
ESC [ 4 q
Emit bad tx tone
ESC [ 5 q
Wait 100 ms
ESC [ 6 q
Turn on the green LED
ESC [ 7 q
Turn off the green LED
ESC [ 8 q
Turn on the green spot
ESC [ 9 q
Turn off the green spot
ESC [ 0 r
Beep for Find me function (new)
ESC [ 1 r
Power-off (new)
Summary of Contents for Gryphon I GM440 Series
Page 42: ...Setup 32 Gryphon I GD44XX GBT4400 GM440X...
Page 46: ...Enter Exit Programming Mode 36 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 60: ...Enter Exit Programming Mode 50 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 102: ...Enter Exit Programming Mode 92 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 248: ...238 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 308: ...References 298 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 338: ...Keypad 328 Gryphon I GD44XX GBT4400 GM440X A B C D E F...
Page 348: ...Scancode Tables 338 Gryphon I GD44XX GBT4400 GM440X NOTES...