Installation and User Guide
DS6x00 EtherNet/IP Scanner
Rev 1.02
6.
Item Data Handshaking Example (No Fragmentation)
The following is an example of how to send 3 Item Data packets, each 300 bytes, with a fragment size of 450.
To Datalogic barcode
scanner from EIP Client
To EtherNet/IP Client from Datalogic Barcode Scanner
Last Item
Sequence
Number
Last Fragment
Sequence
Number
Item
Sequence
Number
Fragment
Sequence
Number
Item
Size
Fragment
Size
Fragment
Data Buffer
Description
0
0
0
0
0
0
NULL
Power Up
1
1
300
300
[0-299]
Datalogic sends complete Item Data 1
1
1
EIP Client acknowledges Item Data 1
2
1
300
300
[0-299]
Datalogic sends complete Item Data 2
2
1
EIP Client acknowledges Item Data 2
3
1
300
300
[0-299]
Datalogic sends complete Item Data 3
3
1
EIP Client acknowledges Item Data 3
© 2004 Datalogic S.p.A. – All Right Reserved
Page 28 of 54