Installation and User Guide
DS6x00 EtherNet/IP Scanner
Rev 1.02
G.
Item Object (0x64)
1.
Class Attributes (Instance 0)
Attribute
ID
Name Data
Type
Data
Value
Access
Rule
1 Revision
UINT 1
Get
2
Maximum Item Data Buffer Size
UINT
450
Get
3
Maximum Fragment Data Buffer Size
UINT
450
Get
2.
Instance Attributes (Instance 1)
Attribute
ID
Name Data
Type
Data
Value
Access
Rule
1
Expected Number Of Barcodes Per Item
USINT
1
Get
2 Item
Status
UINT 0 Get
3
Item Data Size
UINT
0
Get
4
Item Sequence Number
USINT
0
Get
5
Fragment Sequence Number
USINT
0
Get
6
Last Item Sequence Number Received
USINT
0
Get / Set
7
Last Fragment Sequence Number Received
USINT
0
Get / Set
8
Fragment Data Size
UINT
0
Get
9
Fragment Data [ ]
BYTES [ ]
0
Get
3. Common
Services
Implemented for
Service Code
Class Level
Instance Level
Service Name
05
HEX
No Yes
Reset
0E
HEX
Yes
Yes
Get Attribute Single
10
HEX
No
Yes
Set Attribute Single
4.
Class Attribute Semantics
Maximum Item Data Buffer Size
The Maximum Item Data Buffer Size is the maximum length of Item Data. If this attribute is
greater than the Maximum Fragment Data Buffer Size, fragmentation is used to pass the Item
Data. The valid range is 1 – 65535. The default size is 450.
1
This Service Code is used to flush the Item Buffer Queue.
© 2004 Datalogic S.p.A. – All Right Reserved