The C-BOX 4X0 spring clamp connector pinouts are indicated in the following table.
Refer to the scanner Installation Manual for details.
Pin Name
1, 3, 5
VS
2, 4, 6
GND
7, 8
EARTH GROUND
9…12, 20, 33, 34, 40 Reserved
35 TXA
37 RXA
DS2100A
DS2400A
DS4600A Matrix-2000™ Matrix-1000™
21
OUT1+ OUT1+ OUT1+ NC
22
OUT
REF
OUT1- OUT1- NC
23
OUT2+ OUT2+ OUT2+ NC
24
OUT
REF
OUT2- OUT2- NC
25 NC
Reserved
OUT3+
OUT3+
26 NC
Reserved
OUT3-
OUT3-
27
EXT TRIG+
EXT TRIG+
EXT TRIG A
EXT TRIG A
28
EXT TRIG-
EXT TRIG-
EXT TRIG B
EXT TRIG B
29 NC
IN1+
IN
2A
NC
30 NC
IN1-
IN
2B
NC
31 NC
IN2+
NC
NC
32 NC
IN2-
NC
NC
36 RTSA
GND
NC
NC
38 CTSA
SGND
AUX
GND
GND
39 SGND
SGND
GND
GND
NOTE