INSTALLATION
2
2.9.3
Completing C-Box 4x0 Configuration for Matrix-1000™
Readers
CAUTION
When connected to a C-BOX 4x0/4x0, Matrix-1000™ can only
communicate through its Auxiliary Interface.
Once Matrix-1000™ has been configured through VisiSet™ as described in the
previous paragraph, to complete the configuration procedure the C-Box 4x0 must be
reconfigured to accept data from the Matrix-1000™ reader through its Auxiliary
RS232 interface (the only RS232 interface available).
1. Move the C-Box 4x0
Configuration Switch
from the Normal Operation to the
CFG position;
2. Connect the 9-pin internal port of the C-BOX 4x0 to the PC (using a crossover
cable) and run the Winhost™ configuration tool;
3. Select
the
Connect
option to open communications with the C-BOX 4x0 and
wait until the correct communication speed has been determined;
4. From the SCANNER INTERFACE menu, set
Data Source
: Aux Interface
and
save the configuration to the C-Box 4x0 (refer to Figure 18);
5. Return
the
Configuration Switch
to the Normal Operation position;
Figure 18 – WinHost Configuration Menu for C-Box 4x0
6. Close the C-BOX 300.
25
Summary of Contents for C-BOX 400
Page 1: ...C BOX 400 410 Installation Manual...
Page 2: ......
Page 3: ...C BOX 400 410 INSTALLATION MANUAL...
Page 8: ...C BOX 410 2 1 Figure B LCD display Keypad 1 2 vi...