AMT58x-EC EtherCAT®
4
3 - Mechanical installation
WARNING
Installation and maintenance operations have to be carried out by
qualified personnel only, with power supply disconnected. Shaft and
mechanical components must be in stop.
3.1 Solid shaft encoders
Mount the flexible coupling 1 on the encoder shaft;
fix the encoder to the flange 2 (or to the mounting bell) by means
of the screws 3;
secure the flange 2 to the support (or the mounting bell to the
motor);
mount the flexible coupling 1 on the motor shaft;
make sure the alignment tolerances of the flexible coupling 1 are
respected.
3.1.1 Customary installation
a [mm] b [mm] c [mm] d [mm]
AMT58 36
H7
48
-
-
3.1.2 Installation using fixing clamps (code LKM-386)
a [mm] b [mm] c [mm] d [mm]
AMT58 36
H7
-
67
-
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]