AMT58x-CB CANopen®
16
6. CANopen® interface
Datalogic encoders are always slave devices and comply with
“Device profile for encoders”, Class 2.
For any omitted information, refer to the “CiA Draft Standard 301”
and “CiA Draft Standard 406” documents available at www.can-
cia.org.
6.1 EDS file
CANopen® encoders are supplied with their own EDS file
AMT58-
xxx-13x12-CB
(see enclosed documentation or click
D
atalogic
website
).
EDS file has to be installed on CANopen® master device.
6.2 Operation states
CANopen® devices are designed to operate using different states.
Transition from one state to another is made by sending specific
NMT messages (see Figure below).
(1) Power
on
(2)
Initialization carried out, boot-up message is sent
automatically
(3)
NMT message: Start remote node
(4)
NMT message: Enter pre-operational
(5)
NMT message: Stop remote node
(6)
NMT message: Reset node or Reset communication
Initialization
Pre-
ti
l
Operational
Stopped
Boot-up message
(1)
(2)
(3)
(4)
(4)
(5)
(5)
(3)
(6)
(6)
(6)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]