AMT58x-CB CANopen®
7
4. Electrical connections
WARNING
Power supply must be turned off before performing any electrical
connection!
4.1 Connection cap
WARNING
Do not remove or mount the connection cap with power supply
switched ON. Damage may be caused to internal components.
The terminal connectors for connecting the power supply and the
BUS IN and BUS OUT cables (CC-CB connection cap) as well as the
dip-switches meant to set the baud rate and the node ID and activate
the termination resistance are located inside the encoder connection
cap. Thus you must remove the connection cap to access any of
them.
NOTE
Be careful not to damage the internal components when you perform
this operation.
To remove the connection cap loosen the two screws 1.
Please be careful with the internal connector.
Always replace the connection cap at the end of the operation.
Take care in re-connecting the internal connector. Tighten the
screws 1 using a tightening torque of approx. 2.5 Nm.
WARNING
You are required to check that the encoder body and the connection
cap are at the same potential before replacing the connection cap!
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]