6004-00 Position value
[Unsigned32, ro]
This object contains the position value, transmitted value is
calculated considering the scaling values. Value is transmitted
cyclically or synchronously according to the settings in the objects
1800 PDO1 parameters
,
1801 PDO2 parameters
and
1802 PDO3
parameters
.
6200-00 Cyclic time
[Unsigned16, rw]
Cyclic timer value is used in asynchronous transmission mode to set
the interval between two PDO issues. Parameter value is in
milliseconds.
Default = 0000h
6500-00 Operating states
[Unsigned16, ro]
Bit
Function
bit = 0
bit = 1
0
Code sequence
Clockwise CCW
1 not
used
2
Scaling function
Disabled Enabled
3…11 not
used
12
Limit switch min.
posit. >
2104-
00 Limit switch
min.
posit. >
2104-
00 Limit switch
min.
13
Limit switch max.
posit. <
2105-
00 Limit switch
max.
posit. <
2105-
00 Limit switch
max.
14 not
used
15
Current operating state
Stopped
/
Pre-operational
Operational
Code sequence
It shows whether the code sequence is set to clockwise (CW) or
counterclockwise (CCW). To set the code sequence to either CW or
CCW you must set the bit 0
Code sequence
of the object
6000-00
Operating parameters
to 0 / 1.
Scaling function
It shows whether the scaling function is disabled or enabled. To
disable / enable the scaling function you must set the bit 2
Scaling
function
of the object
6000-00 Operating parameters
to 0 / 1.