![DataKinetics DSC110 User Manual Download Page 133](http://html1.mh-extra.com/html/datakinetics/dsc110/dsc110_user-manual_511663133.webp)
DataKinetics DSC110 / DSC210 User Manual Issue 12
Page 133
7.22.8 Remote Data Centre Periodic Data Initiate
RDPDI
Remote Data Centre Periodic Data Initiate
This command attaches a circuit group or outgoing route to a periodic report.
Prerequisites
The report has already been initiated.
The specified circuit group or outgoing route has already been initiated.
Circuit groups can only be specified for MSCGRP reports.
Outgoing routes can only be specified for MSOGR reports.
An association between the report and the circuit group or route has not already
been initiated.
Syntax RDPDI:REPORT=,{[CGRP=…,]|[OGR=…,]}
Attributes CONFIG,
RDC
Example RDPDI:REPORT=1,OGR=1&&8;
7.22.9 Remote Data Centre Periodic Data End
RDPDE
Remote Data Centre Periodic Data End
This command ends the attachment between a circuit group or outgoing route to a
report
Prerequisites
The report has already been initiated.
The specified circuit group or outgoing route has already been initiated.
An association between the report and the circuit group or route has already been
initiated.
Syntax RDPDE:REPORT=,{[CGRP=..,]|[OGR=…,]};
Attributes CONFIG,
RDC
Example RDPDE:REPORT=1,CGRP=1;