DataKinetics DSC110 / DSC210 User Manual Issue 12
Page 105
7.16.36 Configuration Cross Connect Initiate
CNXCI
Configuration Cross Connect Initiate
This command initiates a Cross Connect path across the converter between 2
PCM timeslots.
If DUPLEX is not set to Y then a SIMPLEX Cross Connect is initiated from ITS to
OTS.
Prerequisites
The PCM on which the OTS exists must have already been initiated and the OTS
must be within the correct range for the PCM type (0-31 for E1 and 1-24 for T1
PCMs).
The PCM on which the ITS exists must have already been initiated and the ITS
must be within the correct range for the PCM type (0-31 for E1 and 1-24 for T1
PCMs).
OTS is not already assigned elsewhere on the system for output.
ITS is not already assigned elsewhere on the system for input.
Syntax CNXCI:OTS=,ITS=,[DUPLEX=];
Attributes CONFIG
Example
CNXCI: OTS=5-1-16,ITS=5-1-16,DUPLEX=Y;
7.16.37 Configuration Cross Connect End
CNXCE
Configuration Cross Connect End
This command ends a Cross Connect connection across the converter.
Prerequisites
The OTS must already be initiated as an OTS in a Cross Connect connection path.
If DUPLEX=Y is specified then a duplex connection must already exist for the
specified OTS.
Syntax CNXCE:OTS=,[DUPLEX=,];
Attributes CONFIG
Example CNXCE:OTS=5-1-16;