Appendix A - Agent Capabilities MIB
69
© 2011 Datacom Systems Inc
VARIATION ifAdminStatus
ACCESS read-only
DESCRIPTION "values change according to the
corresponding value of ifOperStatus
as follow:
ifAdminStatus ifOperStatus
------------- ------------
up(1) up(1)
down(2) down(2)
down(3) unknown(4)
"
VARIATION ifOperStatus
ACCESS read-only
DESCRIPTION "only the following states are
implemented:
up(1)
down(2)
unknown(4)
"
VARIATION ifAlias
ACCESS not-implemented
DESCRIPTION "not implemented"
SUPPORTS DATACOM-POWER-SUPPLY-MIB
INCLUDES {
dcomPowerSupplyStatusGroup,
dcomPowerSupplyEventGroup
}
::= { agentCaps 2 }
END
6. Acknowledgments
The production and maintenance of this memo is a group effort of the
Datacom development team.
7. Security Considerations
This module does not define any management objects. Instead, it defines
the top level assignments within the Datacom enterprise name space.