![Datacom Systems VS-1200-S Series User Manual Download Page 27](http://html.mh-extra.com/html/datacom-systems/vs-1200-s-series/vs-1200-s-series_user-manual_511580027.webp)
Initial Configuration
27
© 2011 Datacom Systems Inc
# SE GA 172.169.50.1
Default Gateway will be updated at end of session
#
Or, the parameters can also be entered jointly, (i.e., IP Address, Subnet Mask, Default Gateway)
but entry must be in the proper sequence order and separated by a space delimiter, as shown:
# SET IP [SUBNET] [GATEWAY]
Example:
# SE IP 172.169.50.134 255.255.0.0 172.169.50.1
IP will be updated at end of session
Subnet Mask will be updated at end of session
Default Gateway will be updated at end of session
#
4.1.4.10 SET PORT GROUP (SE PO GR)
This command is used to create a port list under a common name for ease of use. When displayed,
the common name is all caps, regardless of case entry. As part of this command, there is a command
separator (CONTAINS) or, if the OFF parameter (delete the group) is used, the CONTAINS is
not used. A maximum of 10 groups is allowed.
Groups, as designated by the administrator (Superuser,) belong to the same logical group.
Specifically, groups can be configured as if they were a single logical port, enabling a high degree of
control during both the initial setup and all subsequent moves or changes as shown:
SET PORT GROUP (SE PO GR) group name [OFF] or [CONTAINS] port list
Example:
# SE PO GR DatacomPorts CONTAINS 4,5,6
# SE PO GR DatacomPorts OFF
#
4.1.4.11 SET PORT MONITOR (SE PO MO)
This command sets the data routing by selecting the port (output) on which the monitoring device is
to be located as well as ports (input TAPS, SPAN) to be redirected to that monitor port. As part of
this command, there is a command separator (FROM) or, if the OFF parameter (turn off all data
routing to the selected port) is used, the FROM is not used as shown:
SET PORT MONITOR (SE PO MO) comma separated list of port numbers, port names or group
names [OFF] or [FROM comma separated list of port numbers, port names or group names]
Example:
# SE PO MO Port1 FROM Engineering
# SE PO MO 4 FROM 3,2,PortNine