SD Series Installation and Administrator’s Guide
57
9) ExceptionCardImpress
PositionOffset2
2000
2000
[0 – 4000]
10) ExceptionCardImpress
PositionOffset3
2000
2000
[0 – 4000]
11) ExceptionCardImpress
Temperature
130
130
[50 – 160]
12) ExceptionCardNumber
OfImpresses
1
1
[1 – 3]
13) HeaterMinutesToPower
Save
15
15
[15 – 240]
14) Hopper1CardDebow
Direction
Down
Down
15) Hopper1CardDebow
DistanceDown
15
15
[0 – 150]
16) Hopper1CardDebow
DistanceUp
105
105
[0 – 150]
17) Hopper1CardDebow
DwellMs
1000
1000
[0 – 5000]
18) Hopper1CardImpress
Depth
0
0
[-200 – 200]
19) Hopper1CardImpress
DwellTime
2000
2000
[0 – 10000]
20) Hopper1CardImpress
PositionOffset1
2000
500
[0 – 4000]
21) Hopper1CardImpress
PositionOffset2
2000
500
[0 – 4000]
22) Hopper1CardImpress
PositionOffset3
2000
500
[0 – 4000]
23) Hopper1CardImpress
Temperature
130
130
[50 – 160]
24) Hopper1CardNumber
OfImpresses
1
1
[1 – 3]
25) ImpresserSpeed
893
893
[50 – 2000]
Description
Default Value
Current Value
(unit)
Allowed
Range
Summary of Contents for SD260
Page 4: ...iv...
Page 38: ...30 Elements of Card Design...
Page 100: ...92 Supplies and Parts...
Page 116: ...A 16 SD460 Laminating System...