Reading Data
To read the magnetic information from a card, the magnetic field on the card is
used to generate a current in the magnetic head. This is possible because a
moving magnetic field induces a current (or voltage) in a conductor.
The magnitude of the current is dependant on the rate of change of the magnetic
field passing by the head. The greater the change, the larger the current. A simple
way of understanding this is that current will be induced when the read head
cuts through a line of flux. When the read head is traveling parallel to a flux line,
no current will be induced.
Because the flux density is greatest at the poles of a magnet, the current will also
be greatest as the magnetic pole passes below the head. This is illustrated in the
drawing below. If the magnetic stripe were comprised of a single North-to-South
magnet, no current would be induced in the magnetic head for the majority of
the length of the card.
When two North Poles or two South Poles are adjacent to one another, the
magnetic field is compressed and becomes even more dense. The higher the
density of the magnetic field, the larger the current that is induced in the
magnetic head.
For this reason, magnetic data is comprised of
Transition Points
where the
polarity of the magnetism reverses, which results in North-to-North or South-to-
South polarity.
Summary of Contents for CP60
Page 1: ...Datacard CP60 and CP60 Plus Card Printers Service Manual May 2007 Part No 539358 002 Rev C ...
Page 12: ...1 4 Introduction ...
Page 14: ...2 2 Theory of Operation Printer Components Functional Block Diagram ...
Page 19: ...CP60 and CP60 Plus Service Manual 2 7 LCD Menu Diagram ...
Page 50: ...2 38 Theory of Operation ...
Page 124: ...5 40 Adjustments ...
Page 128: ...6 4 Removal and Replacement Front Wire Routing ...
Page 129: ...CP60 and CP60 Plus Service Manual 6 5 Duplex and Printhead Wire Routing ...
Page 130: ...6 6 Removal and Replacement Functional Block Diagram ...