6-20
Removal and Replacement
Ribbon Index Sensor
Removal Procedure
1.
Unplug the printer.
2.
Remove the ribbon cartridge and cleaning roller.
3.
Remove the
4.
Optional: For easier access, you may choose to remove the
(p. 6-42).
5.
Unplug the sensor from the main control board.
6.
Pull the sensor off the mounting post on the ribbon guide. Pry underneath
with a screwdriver if necessary.
Replacement Notes
•
Route the cable through the ribbon guide as shown below.
•
for
replacement details.
•
Use the sensor display in Diagnostics to verify the sensor changes state as the
ribbon is advanced.