6-22
Removal and Replacement
Card Hopper Empty Sensor
The Input Hopper Empty Option has a bracket that clips onto the Card Tray. The
sensor fits into the bracket and plugs into the J40 connector labeled
Spare
.
Even though this sensor displays on the Diagnostics Sensor screen, it is
used only by the printer driver API and is not reported to the driver; it will
have no affect on the printer or error messages from the driver. The sensor
can be utilized only after a programmer has done custom development to
incorporate it.
Removal Procedure
1.
Unplug the printer.
2.
Remove the
3.
Unplug the Hopper Empty sensor from the J40 connector labeled
Spare
. The
plug is located below the CAM Motor.
4.
Pull the wire free from the printer.
5.
Unclip the sensor bracket from the Card Input Hopper.
Replacement Notes
Use Diagnostics to verify that the sensor is working properly.
Sensor
Sensor Bracket
Summary of Contents for CP60
Page 1: ...Datacard CP60 and CP60 Plus Card Printers Service Manual May 2007 Part No 539358 002 Rev C ...
Page 12: ...1 4 Introduction ...
Page 14: ...2 2 Theory of Operation Printer Components Functional Block Diagram ...
Page 19: ...CP60 and CP60 Plus Service Manual 2 7 LCD Menu Diagram ...
Page 50: ...2 38 Theory of Operation ...
Page 124: ...5 40 Adjustments ...
Page 128: ...6 4 Removal and Replacement Front Wire Routing ...
Page 129: ...CP60 and CP60 Plus Service Manual 6 5 Duplex and Printhead Wire Routing ...
Page 130: ...6 6 Removal and Replacement Functional Block Diagram ...