CP60 and CP60 Plus Service Manual
5-35
Start Sentinel Position
Perform this procedure any time you replace any component that can impact
magnetic stripe registration. This includes all magnetic stripe components and
any transport drive component related to moving the card past the magnetic
stripe area.
Mandatory Procedure:
Even if you are manually setting the start sentinel
positions, you must complete the Auto Calibration procedure first.
Adjustment Procedure
1.
Put a magnetic stripe card in the input hopper.
2.
In Printer Diagnostics, click on the
Magnetic Stripe
menu and select
Configuration
.
3.
Click
Calibrate MS Head
. The system will pick the card, pass the card
through the magnetic stripe 10 times, and then eject the card.
•
Note that this card will be blank (all zeros) and will not display data if
read in a card reader. However, it can be developed with magnetic
developing solution.
•
The values (292, 290, and 292) will always be displayed after the
calibration has been completed, regardless what changes were made
during the auto calibration. In a sense, the system was calibrated to make
these values correct.
4.
If the customer requires a custom start sentinel position, alter the numeric
entries for each track in the entry boxes. Since this is custom, you will have to
refer to the customer’s procedure for this setting.
Summary of Contents for CP60
Page 1: ...Datacard CP60 and CP60 Plus Card Printers Service Manual May 2007 Part No 539358 002 Rev C ...
Page 12: ...1 4 Introduction ...
Page 14: ...2 2 Theory of Operation Printer Components Functional Block Diagram ...
Page 19: ...CP60 and CP60 Plus Service Manual 2 7 LCD Menu Diagram ...
Page 50: ...2 38 Theory of Operation ...
Page 124: ...5 40 Adjustments ...
Page 128: ...6 4 Removal and Replacement Front Wire Routing ...
Page 129: ...CP60 and CP60 Plus Service Manual 6 5 Duplex and Printhead Wire Routing ...
Page 130: ...6 6 Removal and Replacement Functional Block Diagram ...