Preparing to Wire Signals
This section provides recommendations and information about wiring signals to a DT9816
Series module.
Wiring Recommendations
Keep the following recommendations in mind when wiring signals to a DT9816 Series
module:
• Follow standard ESD procedures when wiring signals to the module.
• Use individually shielded twisted-pair wire (size 16 to 26 AWG) in highly noisy electrical
environments.
• Separate power and signal lines by using physically different wiring paths or conduits.
• To avoid noise, do not locate the box and cabling next to sources that produce high
electromagnetic fields, such as large electric motors, power lines, solenoids, and electric
arcs, unless the signals are enclosed in a mumetal shield.
• Prevent electrostatic discharge to the I/O while the box is operational.
• Connect all unused analog input channels to analog ground.
Wiring Signals to the DT9816, DT9816-A, DT9816-S, or
DT9816-S-WTR Module
To wire signals to a DT9816, DT9816-A, DT9816-S, or DT9816-S-WTR module, use the screw
terminals on the module, shown in
.
Summary of Contents for DT9816 Series
Page 1: ...DT9816 Series UM 21336 X User s Manual Title Page ...
Page 4: ......
Page 8: ...Contents 8 ...
Page 12: ...About this Manual 12 ...
Page 13: ...13 1 Overview Key Hardware Features 14 Supported Software 16 Getting Started Procedure 19 ...
Page 20: ...Chapter 1 20 ...
Page 21: ...Part 1 Getting Started ...
Page 22: ......
Page 44: ...Chapter 3 44 ...
Page 54: ...Chapter 4 54 ...
Page 55: ...Part 2 Using Your Module ...
Page 56: ......
Page 86: ...Chapter 7 86 ...
Page 102: ...Appendix B 102 ...
Page 108: ...Index 108 ...