■ Running a Job on PSV7000 ◘ Removing Devices
PSV7000 Operator’s Manual
—63—
back
Removing Devices
If unwanted devices are in programmer sockets, they can be removed
in two ways:
Manually
1.
Pause
or
Finish
(end) a job.
2.
Right-click on the desired programmer to open a submenu, and
then click Opener UP.
3.
Using ESD precautions, open a safety door and remove the
devices with a vacuum tweezer.
At the Run Window
1.
Pause
or
Finish
(end) a job.
2.
Click
Clear
.
Stopping the System
There are three methods for stopping the machine:
•
Emergency Stop
—Pushing any of the red E-Stop buttons stops
the movement of the PNP head immediately in an emergency.
(Power to the gantry motors is disconnected and communication
to the Laser head is disconnected.) The AH700 Application must
be closed and the job restarted in TaskLink or LumenX.
•
Pausing a Job
—Clicking
Pause
in the Run window—stops the
PNP head at its next destination. Devices finish programming if
started but are not removed from sockets. The programming
session can be continued.
•
Finish a Job—
Clicking
Finish
in the Run window—stops pick-
ing blank devices, finishes the current programming cycle, and
removes devices from all the sockets placing them into appropri-
ate media. The programming job can be resumed.