FLX500
Chptr 2
—12—
2.
Clear all devices or cards from the sockets
and from the work surface.
3.
Close the
FLX500
Application with the Exit
button.
4.
Turn off the power by pressing the power
switch (right side) once and releasing. Then
push it and release once more to turn it on
again.
The Self-test will begin automatically. Check
that no system errors display on the monitor.
Checking Probe Tips
Tools Required:
• water and lint-free cloth or swab
1.
Clean the rubber PNP probe tips with water
on a clean, lint-free cloth or swab.
2.
Check for wear or cracking; replace the tips
if necessary.
CAUTION: Probe tips could get damaged by
isopropyl alcohol. Do not use isopropyl alco-
hol on the rubber probe tips. It will dry them
excessively, making them prone to cracking
and leaking air.
Cleaning the Fiducials and Sensors
Tools Required:
• shop air, clean and dry,
.48-.55 MPa
(70-80 PSI)
Tray Modules have two fiducial locations and a
sensor, and Programmer Modules have one fidu-
cial location. These fiducials and sensors must be
Data I/O Part Numbers
Probe Tip 4.57 mm OD
288-0019-001
Probe Tip 3.05 mm OD
288-0020-001
Summary of Contents for FLX500
Page 4: ... Data I O FLX500 ii ...
Page 12: ... Data I O FLX500 Chptr 1 8 blank page ...
Page 28: ... Data I O FLX500 Chptr 2 24 blank page ...
Page 40: ... Data I O FLX500 Chptr 4 36 blank page ...
Page 42: ... Data I O FLX500 Chptr 5 38 Daily Sign off Clean the sockets page 10 Date Initials Notes ...
Page 43: ...5 Sign off Charts Daily Sign off 39 Daily Sign off Date Initials Notes ...
Page 44: ... Data I O FLX500 Chptr 5 40 Daily Sign off Date Initials Notes ...
Page 45: ...5 Sign off Charts Daily Sign off 41 Daily Sign off Date Initials Notes ...
Page 46: ... Data I O FLX500 Chptr 5 42 Daily Sign off Date Initials Notes ...
Page 48: ... Data I O FLX500 Chptr 5 44 Weekly Sign off Date Initials Notes ...
Page 52: ... Data I O FLX500 Chptr 5 48 blank page ...
Page 57: ... FLX500 ...