MODEL 2234 DIGITAL FLOW COMPUTER ___________________________
APPENDIX A: READ CODE LISTING
Read
Code
Mnemonic
Term
Title
Feature
FXD
Limits
Ref
Par.
0
DEN
Measured
Density
Displays Measured Density
values in LBF3 (VAR or
FXD)
over 0.1
3.6.2
1
TF
Temperature
Displays Measured
Temperature in degrees
Fahrenheit (VAR or FXD)
-50 to
250
o
F
3.6.2
2
PF
Static
Pressure
Displays Measured Static
Pressure in PSIA (VAR or
FXD)
0.0 to
5000
PSIA
3.6.2
3
MU
Fluid
Viscosity
Displays Fixed or Variable
Viscosity Number
>0.0
3.10
4
IE
Isentropic
Exponent
Displays Isentropic Exponent
Number (FXD)
>0.0
3.10
5
TFS
Temperature
Transducer
Full Scale
Displays Temperature
Transducer Full Scale value
in degrees Fahrenheit (FXD
only)
-
3.6.1
6
TZ
Temperature
Transducer
Zero Scale
Displays Temperature
Transducer Zero Scale value
in degrees Fahrenheit (FXD
only)
-
3.6.1
7
DFS
Densitometer
Full Scale
Displays Analog
Densitometer at Full Scale in
LBF3 (FXD only)
-
3.6.1
8
DZ
Densitometer
Zero Scale
Displays Analog
Densitometer at Zero Scale in
LBF3 (FXD only)
-
3.6.1
APPENDIX A
149