MODEL 2234 DIGITAL FLOW COMPUTER ___________________________
* If no values are given on the calibration certificate for K20B or K21B, A4 and
A5 are set equal to zero. In this case K20 = K20A and K21 = K21A.
Step 2
Enter the results obtained using the appropriate Read Codes.
For the sample
coefficients given above, the proper entries would be as follows:
A0
=
-1.11263
Read Code 30
A1
=
-7.29462
↑
-4
Read Code 31
A2
=
4.08188
↑
-6
Read Code 32
DTC =
-1.2015
↑
-5
Read Code 33
CT
=
68
Read Code 34
TC
=
-2.7566
↑
-5
Read Code 29
P0
=
-1.20897
Read Code 35
K
=
-2.65931
Read Code 36
A4
=
2.12494
↑
-4
Read Code 42
A5
=
-5.7397
↑
-3
Read Code 43
Exercise care to insure applicable units consistency when using the above or similar
relationships. The constants A
0
, A
1
, A
2
must be entered so as to yield density in
gm/cc.