MODEL 2234 DIGITAL FLOW COMPUTER ___________________________
Table 2-1a. Data Entry Example/Guide
(Continued)
Display
Display
Definition
Example
Measurement
Data from
Table 2-2
Actual
Data to
be
Entered
Reference
P. ENTER HF1
Enter full scale
measured
differential
pressure for line
1 in inches of
water
100 ENTR
________
para 2.6.2 (P)
Q. ENTER ID1
Enter inside
diameter of meter
tube for line 1 in
inches
8.071 ENTR
________
para 2.6.2 (Q)
R. ENTER
OD1
Enter orifice
diameter of meter
tube for line 1 in
inches
4 ENTR
________
para 2.6.2 (R)
S. ENTER
TL1
Enter pressure
tap location for
line 1
(1=upstream,
2=downstream)
1 ENTR
________
para 2.6.2 (S)
T. ENTER PA1
Enter plate
expansion
coefficient for
line 1
9.25
↑
-6 ENTER
________
para 2.6.2 (T)
U. ENTER PT1
Enter plate
measurement
temperature for
line 1
60.0 ENTER
________
para. 2.6.2 (U)
SECTION 2
35