![DANIEL 2234 Manual Download Page 26](http://html1.mh-extra.com/html/daniel/2234/2234_manual_509150026.webp)
__________________________
MODEL 2234 DIGITAL FLOW COMPUTER
9.
Up Arrow (
↑
) - Pressing
↑
results in the following actions by
the computer:
a.
Reading data -
↑
causes the computer to step back to the
previous
data
code.
For
example,
if
the
data
corresponding to Read Code 2 is being viewed, pressing
↑
causes the computer to display the data corresponding
to Read Code 1.
b.
Entering data -
↑
indicates to the computer that the data
to follow is an exponent (e.g., 2
↑
5= 2 x 10
5
=200,000).
10.
Down Arrow (
↓
) - Causes the computer to step to the next data
code.
11.
Print (PRNT) - Pressing PRNT sends operator selected data
output to an external printer.
1.2.5 ACCURACY
A.
Low Flow Cutoff - 2% of Full Scale Differential Pressure of lowest
range transducers for each tube.
B.
Density - determined from the Frequency Densitometer input; ±0.1%
of densitometer span for a minimum span of 0.2 LBF3.
C.
Rate Determination - is ±0.1% of full scale.
D.
Temperature Coefficient for Totals - is 0.005%/F.
SECTION 1
14